Overcoming the 100-Device Limit in ControlUp Workflow’s List Devices Node

Posted on October 6, 2026

The ControlUp Workflow List Devices node has a built-in limit of returning only 100 device records per query. This limitation affects workflows attempting to process larger device inventories, such as fetching or looping through over 100 devices. The loop node itself does not have a limit and processes all records provided by the List Devices node. Therefore, the root cause of the problem is the List Devices node restricting the dataset to 100 devices, not the loop processing.

Users trying to obtain results for 500 or more devices found that the List Devices node response capped at 100, blocking workflows from scaling to larger environments. Currently, no filters or tags applied change this default limit on the List Devices node response. This cap is separate from volume limits related to data size, such as the 1GB flow size limit.

As a recommended workaround to bypass this 100-device limit, users can employ the Get Custom Data node to execute custom Data Access Layer (DAL) queries. By enabling the “Get all records” option in this node, workflows can retrieve all devices in the organization without the 100-device limitation. This method was tested successfully with over 400 tagged devices, confirming its viability for larger inventories.

ControlUp representatives acknowledged the 100-device limit in the List Devices node and indicated plans to consider removing or adjusting this restriction in future updates. Until then, users needing to work with more than 100 devices in workflows should use custom DAL queries via Get Custom Data as the primary method to retrieve full device lists.

For further details, users may consult the ControlUp Knowledge Base and official documentation on Workflows and DAL queries at https://docs.controlup.com. The Get Custom Data node and its “Get all records” feature provide a powerful alternative for advanced workflow scenarios that require comprehensive device data beyond the standard node limits.

Read the entire ‘Overcoming the 100-Device Limit in ControlUp Workflow’s List Devices Node’ thread below:

The loop node in Worflows does it have a limit of a 100?


it’s usually the List Devices the kind of node that comes with a limit
any recent change in this node?


No limits there.


and on list devices?


I have set that to 500


Flow has volume limit: 1gb of data


how many results do you see in the node response?


So im trying to get 500 (For now, finel total will be 1200 Devices)
Get the location information and then send it to datadog


and there is no filters?


what do you have here?


Only tag


i could do a “is online”


a moment, I will check in a bigger org.


limit to a 100


The loop is only going through the records obtained by the List Devices node


0-99 -> 100 records
Nothing wrong with the Loop, I believe


Then the list device has a limit of 100


List Devices returns only 100 records for now.


That stops my project


any way that i can work around this?
to list all 500 or 1200 devices?

—, a moment. We need to reach out another team which provide this data. It mast return all devices.


Another workaround would be to use the Get Custom Data node, using custom dal queries


Will that return 1000 devices?


theoretically, yes

—,
so, you can set “Yes” in “Get all records” – in this way you will receive all devices from your organisation.


Testing


tagged 402 devices and getting that

Thanks and
no to tagg the rest


Yes, we have 100 device limit there. My bad for misinforming you previously. We will think about removing this limit.

Continue reading and comment on the thread ‘Overcoming the 100-Device Limit in ControlUp Workflow’s List Devices Node’.  Not a member? Join Here!


Categories: All Archives, ControlUp Workflows

Ask Us Anything, Connect, Learn, and Grow with the ControlUp Community!

Login to the ControlUp Community to ask us anything, stay up-to-date on what’s new and coming soon and meet other like-minded techies like you.

Not already a member? Join Today!

Primary Sidebar

ControlUp Academy

Enroll in ControlUp Academy for expert-led technical training, equipping you with skills to effectively deploy, manage, and grow your ControlUp investment.

Learn here >

Rotating Images

Hidden Gem from our Community on Slack!

ControlUp Betas - What's Coming Next?
NEW ControlUp Features - Stay Up-to-Date!
ControlUp Scripts - Scripting, Zero to Hero
Latest KB Articles - Be the First to Learn

Video Tutorials Library

Visit our technical how-to videos, offering step-by-step tutorials on advanced features, troubleshooting, and best practices.

Watch here >

ControlUp Blog

Check out the ControlUp blog for expert advice and in-depth analysis.

Read here >

ControlUp Script Library

Visit the ControlUp technical script library, which offers a multitude of pre-built scripts and custom actions for your monitoring and troubleshooting requirements.

See here >

ControlUp Support

Visit the ControlUp support home and to delve deeper into ControlUp DEX solutions.

Browse here >

Footer

      

ControlUp Community
Of Techie, By Techie, For Techie!

Terms of Use | Privacy Policy | Security
Dive Deeper, Learn more at ControlUp.com

  • facebook
  • twitter
  • youtube
  • linkedin

© 2023–2026 ControlUp Technologies LTD, All Rights Reserved.

We use cookies to ensure that we give you the best experience on our website. by continuing to use this site you agree to our Cookie policy..