A user asked if anyone is using EdgeDX and Beyond Trust Endpoint Privilege Management (Avecto) in their environment and experiencing issues with Teams crashing or not opening. ControlUp has exclusions in place, but the issue persists. Following registry entries should indicate exclusions put in place by the Avecto team. Communications between ControlUp and Avecto support may be necessary to troubleshoot the issue further.
Read the entire article here...
Physical Desktops Related Training & Support Archives
Physical Desktops training and support-related archives from inside the ControlUp Community on Slack.
What Condition Should I Use to Set Up an Alert in Solve for Edge DX When a Ping is Missed?
To set up an alert in Solve for Edge DX when a ping is missed. What condition would I use?
Read the entire article here...
Read the entire article here...
Understanding ControlUp Edge DX Geolocation
Edge DX and geolocation issues were discussed; Windows Location Services is used and if not enabled the ISP is looked up, followed by a default centre in Wichita. An article was suggested for further info - https://support.controlup.com/docs/device-geolocation.
Read the entire article here...
Read the entire article here...
Can ControlUp Real-Time Be Deployed in an On-Premise Environment?
A user asked if it was possible to deploy Real-Time Diagnostics in an on-premise environment, which is possible with a fully on-premise solution. HP thin clients can be added to Edge DX, which is cloud-only and can get remote DX data from them but not the devices themselves.
Read the entire article here...
Read the entire article here...
How to Determine Device Presence and Last Communication Value in ControlUp Edge DX
A user asked about EdgeDX API, looking for a best Index to use and if an API request should be sent for each device. It was suggested to use the (hidden) _devices index and take inspiration from the Edge UI, which can be accessed by pressing F12. Lastly, using the Get-EdgeDXIndexData with a maxrecord of 10000 was suggested which would retrieve all the records.
Read the entire article here...
Read the entire article here...
Edge DX Agent Beta Bits & Auto Update Agent
A user experienced the Edge DX agent reverting from the beta version to the non-beta version due to Auto Update Agent being enabled. Questions were asked about the version which should be showing if the user is on Beta, and answers indicated that version 2.12.0.2162 is the current version. The File transfer feature was mentioned as a benefit. The explanation for the reverting was that the user had to choose one of the Beta versions in the Agent section of Settings.
Read the entire article here...
Read the entire article here...
Health Checks for VMware UAGs Using Horizon and UAG APIs within ControlUp
A user asked for suggestions on what metrics to assess in a project to do better health checks on VMware UAGs using Horizon and UAG APIs. Ideas include alerting when a connection server exceeds a threshold, and when services are not in a running state, as well as low available memory and high CPU. These metrics would also be desirable to display in ControlUp's Solve and Console. Discussions also included Dennis' idea to bring the data to Edge DX and a feature request for UAG data.
Read the entire article here...
Read the entire article here...
How to Make ControlUp Edge DX Recognize Windows-Based Thin Clients
A user was having an issue with Windows-based thin clients not showing up properly on Edge DX when the device image was sysprepped and reinstalled. Edge has a UID stored in the programdata folder which marks the device as unique. To solve this issue, the UID must be removed before sealing the image, and then a new UID will be generated when the Edge agent is restarted. The UID file can be found in C:\programdata\Avacee\sip_agent\cachefiles.
Read the entire article here...
Read the entire article here...
Tackling Peak User Input Delay (secs) with ControlUp
Trentent gave advice seeking to identify why application performance on physical machines had a peak user input delay up to 15 seconds - the default trigger priority boost for processes has a threshold of 300ms. Edge DX was installed and CPU spikes were not observed. It was fixed in the Beta 2 for Windows and can be due to any number of causes such as latency with proxies and disk issues. User input delay can be inspected with the newest agent.
Read the entire article here...
Read the entire article here...
How to Kick off Windows Systemreset Command from ControlUp Edge DX?
A user wondered if there was a way to kick off the Windows "systemreset -factoryreset" command with a script from Edge, as an alternative to the user going into recovery mode, but it seems that a prompt is required which will be unanswered if the user is not logged on. The user would not like to automate this process and the solution may not be worth the effort required to make it 100% safe.