Users were experiencing slow load times when interacting with the Devices page, and believed it was due to seeing too many devices at once being set at 100. It was suggested to switch to 10 or 20 devices to improve responsiveness, however this was previously set up to 50 devices without issues. Coincidentally, users also noticed the online column now had color shading, but this was unrelated, as this was due to different filters being set.
Read the entire article here...
ControlUp Community Training & Support Archives
All training and support-related archives from inside the ControlUp Community on Slack.
Troubleshooting ControlUp Trigger Not Working
A user was having trouble with their trigger not working, and questions were raised about setting values and checking boxes. It was suggested to remove "from this state" as it was optional, and to try setting a filter of from: greater than 30 to: less than or equal to 30. It was also noted that in the upcoming release of 9.0, this feature of seeing free space for mapped drives and being able to alert on them would be available. Finally, it was suggested to remove "from this state" and check if the monitor had to be restarted.
Read the entire article here...
Read the entire article here...
How to get more that 14 day of history in the ControlUp “Incidents” window ?
The user asked if there was a way to get more than 14 days of history in the ‘Incidents' window and more than 1-hour of history in the 'Events' view. The response was that ‘Incidents’ this is not possible, however ‘Events’ can be increased by increasing RAM, which will increase the console footprint. The user then asked if a feature request could be sent for ‘Incidents’ history window. The response was that this could be done, although the audit data can be sent to syslog server in order to query for more than 14 days.
Read the entire article here...
Read the entire article here...
Can I add an EUC environment when the site name is the same in ControlUp?
A user was unable to add an EUC environment due to the same site name. The workaround suggested is to temporarily rename one of the sites, add it to ControlUp, and then renaming it back.
Read the entire article here...
Read the entire article here...
Can ControlUp Real-Time Be Deployed in an On-Premise Environment?
A user asked if it was possible to deploy Real-Time Diagnostics in an on-premise environment, which is possible with a fully on-premise solution. HP thin clients can be added to Edge DX, which is cloud-only and can get remote DX data from them but not the devices themselves.
Read the entire article here...
Read the entire article here...
Is there a sizing guide to how much storage space you need for ControlUp Inights
A user asked about sizing for Insights storage - in the KB, an example of 1,000 RDSH, 500 VDI and 30 Server OS users was given as 3 TB per year with an overhead of 1.3. 8,000 Citrix users, 2,000 VDIs, 3,000 laptops and 1,000 servers will require around 48 TB of storage, which would need an IOP cluster with 3 data nodes. The article from ControlUp KB is no longer available, however ControlUp's Knowledge Base article on prerequisites for Insights on-premises can be found at https://support.controlup.com/v1/docs/insights-on-premises-prerequisites#recommended-installation-types-based-on-sessions.
Read the entire article here...
Read the entire article here...
Why Separate Monitors and Data Collectors for ControlUp?
It is important to separate Monitors from Data Collectors in order to avoid competing for resources as well as breaking up extensions into chunks. Many companies opt for 8 Data Collectors, while some run Data Collector on Monitor servers if there is no sizing issue. Further resources concerning Data Collectors can be found at ControlUp's blog article and KB page (https://www.controlup.com/resources/blog/entry/what-is-a-data-collector-and-why-does-it-matter, https://support.controlup.com/docs/controlup-data-collector).
Read the entire article here...
Read the entire article here...
How to get the IGEL Device Name vs. the MAC Address with ControlUp Remote DX?
The user asked about how the naming of an IGEL thin client works, as it appears in the COP and in scripts. The network name had not been set, so it appeared differently in UMS and COP, and the scripts gave an error. By setting the Network Name, it should appear consistently across the platform. For more information, please see https://kb.igel.com/endpointmgmt-6.08/en/renaming-igel-os-devices-47711460.html.
Read the entire article here...
Read the entire article here...
Is the ControlUp “Forecasting” Feature Supported on On-Prem?
A user asked if the "Forecasting" feature for Insights Reports was supported on On-prem infra, specifically for the Host Trends report. They were told that it was not available on-prem, and that there were no plans to add this to IOP at this time.
Read the entire article here...
Read the entire article here...
Error: “Install .NET FW 4.8 on the target machine” Upgrading ControlUp Monitors
A user was trying to upgrade ControlUp Monitors from 8.7.0.579 but kept getting a message to install .NET FW 4.8 on the target machine. This is a known issue which is fixed either by patching or uninstalling a patch (specifically ms patch kb5011048). Rolling back the upgrade was the current solution, but the user had the current version 4.8 (not 4.8.1) and a clean install worked. The KB article for this issue is: Error when deploying ControlUp Monitor: Install .NET FW 4.8 on the target machine.
Read the entire article here...