Edge DX and geolocation issues were discussed; Windows Location Services is used and if not enabled the ISP is looked up, followed by a default centre in Wichita. An article was suggested for further info - https://support.controlup.com/docs/device-geolocation.
Read the entire article here...
ControlUp for VDI (Real-Time DX) Training & Support Archives
ControlUp for VDI (Real-Time DX) training and support-related archives from inside the ControlUp Community on Slack.
Does the Bandwidth Limit metric come from the Citrix EDT logic?
A question was asked about the Bandwidth Limit metric from the Citrix EDT logic - this is estimated by sending two packets of known size and measuring the time it takes to transmit them. The metric is measured in Mbps and it should not be lower than 1 or 2 Mbps as Citrix is nimble in its bandwidth consumption. Thanks to @member for clarifying.
Read the entire article here...
Read the entire article here...
Dell Wyse Thin Clients stopped receiving ControlUp Remote DX information since updating to the latest firmware
A user reported that the ControlUp agent was not working with the Dell Wyse ThinOS 2303 firmware and mentioned that Dell may need to be involved with the new update. It was suggested that a Dell case should be opened. After some further investigation, the user found that a module.ini setting had been added which caused the ControlUp agent to not load, and removing the entries fixed the issue.Title: ControlUp Agent Not Working After Dell Wyse ThinOS 2303 Firmware Update
Read the entire article here...
Read the entire article here...
Can I add an EUC environment when the site name is the same in ControlUp?
A user was unable to add an EUC environment due to the same site name. The workaround suggested is to temporarily rename one of the sites, add it to ControlUp, and then renaming it back.
Read the entire article here...
Read the entire article here...
Can ControlUp Real-Time Be Deployed in an On-Premise Environment?
A user asked if it was possible to deploy Real-Time Diagnostics in an on-premise environment, which is possible with a fully on-premise solution. HP thin clients can be added to Edge DX, which is cloud-only and can get remote DX data from them but not the devices themselves.
Read the entire article here...
Read the entire article here...
Why Separate Monitors and Data Collectors for ControlUp?
It is important to separate Monitors from Data Collectors in order to avoid competing for resources as well as breaking up extensions into chunks. Many companies opt for 8 Data Collectors, while some run Data Collector on Monitor servers if there is no sizing issue. Further resources concerning Data Collectors can be found at ControlUp's blog article and KB page (https://www.controlup.com/resources/blog/entry/what-is-a-data-collector-and-why-does-it-matter, https://support.controlup.com/docs/controlup-data-collector).
Read the entire article here...
Read the entire article here...
How to get the IGEL Device Name vs. the MAC Address with ControlUp Remote DX?
The user asked about how the naming of an IGEL thin client works, as it appears in the COP and in scripts. The network name had not been set, so it appeared differently in UMS and COP, and the scripts gave an error. By setting the Network Name, it should appear consistently across the platform. For more information, please see https://kb.igel.com/endpointmgmt-6.08/en/renaming-igel-os-devices-47711460.html.
Read the entire article here...
Read the entire article here...
Can I remove\organize\curate the list of ControlUp Script Actions in the right-click context menu?
The user asked about curating the right-click action list in ControlUp - by using a prefix with the company and script name, the scripts can be filtered and found more easily in the Console. Renaming a community script with a prefix may orphan it from future updates. Virtual Expert rules can also be used to organize the columns. The user also mentioned using Site Monitor on a trigger to dump a CSV onto a share.
Read the entire article here...
Read the entire article here...
After upgrading Citrix VDA to 2203CU2 have noticed the HDX Latency to be erroneous and erratic?
Users reported incorrect HDX Latency and Round Trip Time (RTT) values in Citrix VDA versions 2112 and earlier. The issue can be fixed by disabling the HDX Adaptive Scaling feature in the VDA registry (CVADHELP-19781). Changing the CU setting to current value and disabling Remote DX latency may also help. More information can be found in the Citrix documentation at https://docs.citrix.com/en-us/citrix-virtual-apps-desktops/2203-ltsr/whats-new/cumulative-update-1/fixed-issues.html.
Read the entire article here...
Read the entire article here...
Troubleshooting “Install Agent” Status with ControlUp
A user encountered a problem with a machine not being able to install an agent after re-appearing with an "Install Agent" status. The solution was to add the machine to the tree on the left and then use "agent control/Upgrade/installah" to complete the installation. This process worked successfully.
Read the entire article here...