• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer
ControlUp Community

ControlUp Community

Connect, Learn, and Grow

  • Blog
  • Archives
  • Findings
  • Meetups
  • Videos
  • Events
  • Categories
    • ControlUp One Platform
    • ControlUp for Apps
    • ControlUp for Compliance
    • ControlUp Dashboards
    • ControlUp for Desktops
    • ControlUp for VDI
    • ControlUp Scripts & Triggers
    • ControlUp Synthetic Monitoring
    • ControlUp Workflows
  • Topics
    • Logos & Wallpaper
    • ControlUp.com
  • Join

ControlUp for VDI (Real-Time DX) Training & Support Archives

ControlUp for VDI (Real-Time DX) training and support-related archives from inside the ControlUp Community on Slack.


Troubleshooting with Microsoft AVS and ControlUp for vSAN and vSphere Monitoring

Posted on September 10, 2024

A user asked about using Microsoft AVS solution and ControlUp to monitor vSAN/vSphere hosts. It was noted that Microsoft does not allow turning on vSAN Performance Service "Read" permissions, which is required for monitoring. ControlUp gives back ERR in all the metrics columns. It was mentioned that a jumpbox may be needed for setup and that access is limited. The article available here (https://support.controlup.com/docs/vsan-prerequisites) may be helpful for troubleshooting.

Read the entire article here...


Navigating Permissions and Training at ControlUp Academy

Posted on September 9, 2024

ControlUp Academy is a training platform for ControlUp software, offering free self-training and instructor-led content. Users can also obtain ControlUp certifications through the Academy at https://cuacademy.controlup.com/. Additionally, the discussion touched on permissions and login methods for the RT console, with @member providing tips on using SAML and ControlUp groups to resolve issues. The Academy can assist with further training on this topic.

Read the entire article here...


Triggering Actions based on Specific Server Connection Failures in ControlUp Real Time Console

Posted on September 5, 2024

A discussion was held about being able to trigger an action based on the number of connection failures for a specific server. It was suggested to add a column in the Real Time Console to display the number of Citrix connection failures, which could then be used to create triggers. The user also asked about improved local host cache monitoring and the possibility of bringing it into the product. The ControlUp support team mentioned some relevant resources and offered to discuss further during an upcoming meeting.

Read the entire article here...


Upgrading to the Latest Version of ControlUp and Switching Datastreams

Posted on September 4, 2024

A user asked if they could upgrade directly from their current version to the latest version of ControlUp and then change the datastream, or if they needed to go through multiple versions. Another user responded that they could upgrade directly and would be switched over to the streaming, with the team being notified ahead of time. It was suggested for the user to DM their organization name to have it added to the migration list.

Read the entire article here...


Reducing Network Traffic between vCenter and ControlUp

Posted on September 4, 2024

A user asked about the high amount of network traffic between their vCenter and ControlUp. This could be due to the SOAP-based data collection, which would appear as HTTP traffic. It was suggested to run diagnostics on the data collector to confirm, and to consider creating a ControlUp site closer to the vCenter to reduce data traffic. Contacting a CSM or via DM was also recommended for further assistance. Event

Read the entire article here...


Troubleshooting AppX Load Packages in ControlUp

Posted on August 28, 2024

A user was trying to figure out the discrepancy in the AppX load packages duration time and asked for clarification. Another user mentioned that the gap in the total duration was 2 seconds, caused by the operating system. They suggested disabling appx packages or checking storage speeds and profile sizes to improve login duration. Another user added that ControlUp shows what it knows to look for, but there may be other things happening that are not logged or classified yet. The original user thanked both for their helpful responses.

Read the entire article here...


Refresh Time for API Connection in ControlUp RealtimeDX

Posted on August 22, 2024

A discussion was held about the refresh time for the API connection and RealtimeDX or Data Collector. It was mentioned that the data collection time for Horizon can be seen through invoke-cuquery, with a cycle starting every 10 seconds after the previous cycle is completed. The RealtimeDX version being discussed is 9.0.0.1680.

Read the entire article here...


Limitations of RemoteDX and EdgeDX for Non-Windows Devices in ControlUp

Posted on August 21, 2024

A user was experiencing difficulty connecting to the physical endpoint with Edge DX from a VDI session. The link between RemoteDX and EdgeDX is currently only supported for Windows devices, and there are no plans for future support. This limitation can be reported and upvoted on Uservoice. The "jump to device" functionality may still be possible by copying the device name and searching for it in the device details tab. There is currently no documentation or mention of this limitation being a known issue or unsupported in the release notes or knowledgebase. It is believed to be due to the ability for RemoteDX to pull the device ID from Windows, which is not built in for Linux/IGEL/thin clients.

Read the entire article here...


Troubleshooting EUC Connection in Citrix 2407

Posted on August 19, 2024

After upgrading a lab to Citrix 2407, a user noticed EUC Connection was no longer working and opened a ticket. The property 'VMPoweredOnDate' does not exist on type 'XenDesktopMonitor.XenDesktopMonitorV2.Connection'. A suggested method for troubleshooting is also mentioned.

Read the entire article here...


Configuring Retention Policy for ControlUp Monitoring Data

Posted on August 19, 2024

A user asked about configuring a retention policy for monitoring data in real-time dx and edge dx. The only article found was for managing retention in Cu Insights, which is out of date. However, it was noted that this is managed from the backend with a default of 365 days for real-time and 30 days minimum for edge dx.

Read the entire article here...


  • « Go to Previous Page
  • Page 1
  • Interim pages omitted …
  • Page 19
  • Page 20
  • Page 21
  • Page 22
  • Page 23
  • Interim pages omitted …
  • Page 50
  • Go to Next Page »

Primary Sidebar

ControlUp Academy

Enroll in ControlUp Academy for expert-led technical training, equipping you with skills to effectively deploy, manage, and grow your ControlUp investment.

Learn here >

Rotating Images

Hidden Gem from our Community on Slack!

ControlUp Betas - What's Coming Next?
NEW ControlUp Features - Stay Up-to-Date!
ControlUp Scripts - Scripting, Zero to Hero
Latest KB Articles - Be the First to Learn

Video Tutorials Library

Visit our technical how-to videos, offering step-by-step tutorials on advanced features, troubleshooting, and best practices.

Watch here >

ControlUp Blog

Check out the ControlUp blog for expert advice and in-depth analysis.

Read here >

ControlUp Script Library

Visit the ControlUp technical script library, which offers a multitude of pre-built scripts and custom actions for your monitoring and troubleshooting requirements.

See here >

ControlUp Support

Visit the ControlUp support home and to delve deeper into ControlUp DEX solutions.

Browse here >

Footer

      

ControlUp Community
Of Techie, By Techie, For Techie!

Terms of Use | Privacy Policy | Security
Dive Deeper, Learn more at ControlUp.com

  • facebook
  • twitter
  • youtube
  • linkedin

© 2023–2026 ControlUp Technologies LTD, All Rights Reserved.

We use cookies to ensure that we give you the best experience on our website. by continuing to use this site you agree to our Cookie policy..